Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-045-22266C&C Energy
GM 522-13
TEP ROCKY MOUNTAIN LLC
96850
PR
8/4/2014
GRAND VALLEY
31290
PARACHUTE/GARFIELD  045
SWSW 12 7S96W 6
334722View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400467281
10/04/2013
(1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. SEE ATTACHED NOTICE. (2) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE GARFIELD COUNTY RULISON FIELD NOTICE TO OPERATORS IS REQUIRED, WITH THE FOLLOWING EXCEPTION: ALL FIELD NOTICE REQUIREMENTS SPECIFIED IN THIS NOTICE TO OPERATORS ARE SUPERSEDED BY THE REQUIREMENTS OF THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY (SEE CONDITION OF APPROVAL #1). SEE ATTACHED NOTICE. (3) CEMENT ON PRODUCTION CASING MUST BE A MINIMUM OF 200' ABOVE THE TOP OF THE MESA VERDE FORMATION (OR 200' ABOVE THE OHIO CREEK FORMATION IF PRESENT). CEMENT TOP VERIFICATION BY CBL IS REQUIRED.
EngineerForm: (04)
401916883
01/30/2019
1) Venting to maintain the bradenhead pressure below 0.25 times the surface casing setting depth (TVD) in psi is approved. Perform annual Bradenhead tests reported on a Form 17 and an annual update sundry with the duration of venting or number of times the annulus was vented. 2) COGCC staff encourages the use of a combustor for vented bradenhead gas when feasible without the use of supplemental fuel for the combustor. An enclosed flare shall be used, unless an open flare is specifically allowed by Colorado Department of Public Health and Environment (CDPHE) Regulation 7. 3) Comply with any CDPHE, Air Pollution Control Division rules or requirements for all atmospheric discharges. 4) Any liquids blown down are to be collected, stored, handled, and treated or disposed as E&P waste per COGCC’s 900 series rules. 5) Annular spaces may be tied to low pressure sales lines with COGCC engineering approval on a Sundry Notice, Form 4, describing equipment configuration, proper pressure regulation and check valves. At least one check valve is required for annular spaces that are tied to sales. Maintain equipment for pressure regulation and check valves in good working order. 6) Submit a Form 4 Sundry within 60 days providing the COGCC a measured rate of vented bradenhead gas.
EngineerForm: (04)
402298725
02/25/2020
1)Venting to maintain the bradenhead pressure below 0.25 times the surface casing setting depth (TVD) in psi is approved. Perform annual Bradenhead tests reported on a Form 17 and an annual update sundry with the duration of venting or number of times the annulus was vented. 2)COGCC staff encourages the use of a combustor for vented bradenhead gas when feasible without the use of supplemental fuel for the combustor. An enclosed flare shall be used, unless an open flare is specifically allowed by Colorado Department of Public Health and Environment (CDPHE) Regulation 7. 3)Comply with any CDPHE, Air Pollution Control Division rules or requirements for all atmospheric discharges. 4)Any liquids blown down are to be collected, stored, handled, and treated or disposed as E&P waste per COGCC’s 900 series rules. 5)Annular spaces may be tied to low pressure sales lines with COGCC engineering approval on a Sundry Notice, Form 4, describing equipment configuration, proper pressure regulation and check valves. At least one check valve is required for annular spaces that are tied to sales. Maintain equipment for pressure regulation and check valves in good working order.
EngineerForm: (04)
402818210
09/30/2021
1) Operator shall comply with COGCC Rule 419. Bradenhead Monitoring, Testing, and Reporting and Rule 420. Form 17, Bradenhead Test Report 2) At least once a year shut in bradenhead for 7 days or until the pressure reaches the bradenhead threshold and perform a bradenhead test. Report results on a Form 17, as specified in Rule 420 or other Director approved submittal method. 3) Comply with any CDPHE, Air Pollution Control Division rules or requirements for all atmospheric discharges. 4) Any liquids blown down are to be collected, stored, handled, and treated or disposed as E&P waste per COGCC’s 900 series rules. 5) At least one check valve is required for annular spaces that are tied to sales line or separator. Maintain equipment for pressure regulation and check valves in good working order.
 
COGIS - Best Management Practice Results
No records to display.