Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-045-22158PA
701-32-HN1
TEP ROCKY MOUNTAIN LLC
96850
PR
1/17/2015
PICEANCE HORIZONTAL NIOBRARA
68810
GARFIELD  045
NWSW 32 6S95W 6
335311View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400448375
08/19/2013
(1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. (2) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE GARFIELD COUNTY RULISON-FIELD NOTICE TO OPERATORS IS REQUIRED.
EngineerForm: (02)
400448946
08/19/2013
(1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. (2) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE GARFIELD COUNTY RULISON-FIELD NOTICE TO OPERATORS IS REQUIRED. (3) CEMENT ON PRODUCTION CASING MUST BE A MINIMUM OF 200’ ABOVE THE TOP OF THE MESA-VERDE FORMATION (OR 200’ ABOVE THE OHIO CREEK FORMATION IF PRESENT). CEMENT TOP VERIFICATION BY CBL IS REQUIRED.
OGLAForm: (04)
400650248
08/05/2014
A closed loop system must be implemented during drilling; or, if a drilling pit is constructed, an amended Form 2A must be submitted and a Form 15 submitted if operator plans on using either oil based mud or high chloride/TDS mud. The pit must be lined. All cuttings generated during drilling with oil based mud or high chloride/TDS mud must be kept in the lined drilling pit (if permitted and constructed), tanks/containers, or placed on a lined/bermed portion of the well pad; prior to disposition. The moisture content of any drill cuttings in a cuttings containment area or pile shall be as low as practicable to prevent accumulation of liquids greater than de minimis amounts. At the time of closure, if the drill cuttings are to be left onsite, they must also meet the applicable standards of table 910-1. Representative cuttings samples will be analyzed for all Table 910-1 constituents. Any material which does not meet Table 910-1 criteria will either be manifested and disposed offsite at an approved commercial facility, sent to a permitted WPX Cuttings Management Trench for additional amending (Form 4 Sundry must be submitted and approved), or amended further onsite to comply with Table 910-1. If operator determines that long-term onsite management of oil based mud or high chloride/TDS mud cuttings is necessary, an approved Form 27 remediation plan will be required. All liners associated with oil based or high chloride/TDS drilling mud and cuttings must be disposed of offsite per CDPHE rules and regulations.
EngineerForm: (05)
400821318
11/10/2015
asked for CBL (or other TOC determination) for int (9.625") string. will possibly require Form 4 Request for variance of not meeting Piceance TOC COA what is actual casing set date and TD reached date? (can't be the same as for wellbore "00")
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (04 )
400650248
8/5/2014
A Katch Kan Zero Spill System or equivalent will be utilized under the sub-structure so that if anything is spilled on connections it can be easily transferred back into the system and cleaned up with floor dry. All transfer hoses should be checked to insure that the cam-lock couplings have gaskets prior to connection. It is advised to secure the cam-locks with wire to prevent them from coming undone. All gates must be closed, chained and locked. They should be sealed with silicone caulking or packed tightly with fresh gel. This is done to insure that no leakage will occur after the SBM in transferred into the active pit system. Drip pans should be placed to catch any potential spills. Drip pans should also be placed in the loading and unloading area. Once the SBM is transferred the transfer lines should be capped with a cam-lock cap or plug. Spills will be excavated and contaminated soil will be hauled to a commercial solid waste disposal facility.