Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-045-12343CHEVRON
5-2D
QB ENERGY OPERATING LLC
10844
PR
1/12/2010
GRAND VALLEY
31290
GARFIELD  045
SWNW 4 6S96W 6
335597View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04)
400507961
12/02/2013
BHP = 540 psi. Vent off high BHP through a hard-line to a tank for 90 days. Record BHP (if any) at that time. Shut-well in for 48 hours. Record 48-hour build-up BHP and report to COGCC. Add'l venting and/or remediation may be required.
EngineerForm: (04)
400749263
12/15/2014
Approval for 90 day venting is granted. Due to rapid blowdown time reported on 12/31/2013 (doc#2122053) verify that their is not a buried valve that is closed. Shut-in well for 48 hours after 90 days. Record BHP @ conclusion of shut-in period and furnish results to COGCC. Comply with all applicable CDPHE rules and regulations.
 
COGIS - Best Management Practice Results
No records to display.