| UIC | Form: (04) 401072046 07/07/2016 | Operator required to submit Form 4-Sundry Notice for Rule 502.b Variance Request because Packer is set 362' above top perforation. Rule 326.a.(1).A says in part: "Isolation of the tubing-casing annulus with a packer set at 100 feet or less above the highest open injection zone perforation, unless an alternate isolation distance is approved in writing by the Director." |
| UIC | Form: (04) 401072046 07/07/2016 | Operator required to submit Form 5A-Completed Interval Report to report new tubing and packer inforamation. Include as an attachment a wellbore diagram showing the stuck packer and current tubing configuration. |
| Engineer | Form: (04) 401982484 04/05/2019 | The Operator shall monitor the bradenhead pressure of this well during the proposed procedure. Operator shall notify COGCC Engineering staff of bradenhead pressures greater than 150 psig and submit a Form 17. |