Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-045-06956CLOUGH
RMV 25-20
TEP ROCKY MOUNTAIN LLC
96850
PR
3/27/1995
RULISON
75400
GARFIELD  045
NWSE 20 6S94W 6
335236View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04)
403791290
09/18/2024
Operator shall continue to monitor pressure and report to ECMC through annual testing. If monitored well conditions meet the thresholds a new bradenhead test and sundry must be filed.
EngineerForm: (04)
404614366
04/22/2026
1. Operator will implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare. 2. Bradenhead gas is not to be vented to atmosphere; any gas from the Bradenhead will be routed to the specified abatement system. Operator will implement measures to get an initial estimate of the gas flow rate and/or volume from the bradenhead. The abatement program may be used for six consecutive months. 3. Operator will submit a Form 42 (“OTHER”) stating that “bradenhead abatement program has started.” 4. At the conclusion of the six months (from installation of pressure mitigation system), conduct a new bradenhead test and submit the Form 17 within ten days of the test and submit a Form 4 Sundry that summarizes current well condition. The sundry should include details of the future plans, flow rate information, pressure data and a discussion of the sample analysis. 5. At least one check valve is required for annular spaces that are to an abatement system. Maintain equipment for pressure regulation and check valves in good working order. 7. At least one valve is required to monitor pressure and sample flow from the bradenhead. 8. Within 30 days of completing the work, submit a Form 4 Subsequent Report including a schematic of the bradenhead tie in
 
COGIS - Best Management Practice Results
No records to display.