WELL05-045-06870CASCADE CREEK
609-1
OXY USA WTP LP
66571
PA
2/28/2014
GRAND VALLEY
31290
GARFIELD  045
NWSW 9 6S97W 6
323892View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
400518149
1/7/2014
changed P&A procedure step of balanced in-casing plug from 2900' to 2000' w/100 sx to perf-&-squeeze 50' below surface shoe (2125') step. CICR @ 2025' +/- would be good idea. This substitution can be bypassed if circulation is not possible from perfs outside surface casing to surface through annulus -- in which case OPR reverts back to originally-proposed step.
Reclamation SpecialistForm: (04 )
403237273
11/29/2022
Remediation project #9257 remains active on the Location; closure and reclamation of the remediation project will be required prior to final passing of the Location itself.
 