Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-045-06707BARRETT ET AL
TW 8-36
TEP ROCKY MOUNTAIN LLC
96850
PA
10/2/2014
GRAND VALLEY
31290
GARFIELD  045
NWSW 36 6S96W 6
335253View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04)
400560949
03/08/2014
WPX is instructed to submit a COGCC form 6 – Well Abandonment Report –Notice of Intent complete with well bore diagrams (WBD) depicting before and after plugging. There is not an approved one in the COGCC well file. The operator is required by rule 311 to do so prior to plugging the well. When the work is completed, another COGCC form 6 – Well Abandonment Report-Subsequent Report of Abandonment complete with an as plugged WBD and supporting service company job tickets.
EngineerForm: (06)
400591936
08/21/2014
1) Plug added: provide balance plug in casing across squeezed HIC at 773'. Minimum 10 sxs from 823' to 723'. 2) Modify procedure as follows: perforate casing 100' below surface casing shoe (396') and place plug in annulus and casing from 396' to 246'. If a CICR is not used, tagging the plug is required. Tag plug at 246' at least 50' above surface casing shoe.
 
COGIS - Best Management Practice Results
No records to display.