Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-005-06677STATE
3-26
KP KAUFFMAN COMPANY INC
46290
PA
8/26/2014
SIDEWINDER
77458
ARAPAHOE  005
NENW 26 4S62W 6
320707View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400667612
08/20/2014
NOTE: Changes in plugging procedure - additional plugs 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Provide 10 sx plug at the surface (inside and outside of casing). Leave at least 100’ cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
 
COGIS - Best Management Practice Results
No records to display.