| Engineer | Form: (02) 400248521 02/24/2012 | 1) Note surface casing setting depth change from 1710’ to 1820’. Increase cement coverage accordingly.
2) Provide 24 hour notice of MIRU to COGCC inspector Mike Hickey via e-mail at Mike.Hickey@state.co.us. Indicate Spud Notice in the subject line and provide the following information: Operator Name, Well Name and Number, API #, Spud Date, Contact Name, Contact Phone #, E-mail Address. If well spud after April 1, 2012 submit Form 42 electronically to COGCC 48 hours prior to MIRU.
3) Comply with Rule 317.i and provide cement coverage from end of 7" casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
4) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
|
| Permit | Form: (02) 400248521 03/29/2012 | Operator will run open hole logs into surface casing on the first well drilled on this pad, either this well or the Venturers 41-4H. |