Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-001-08879KRAFT
34-14
EXTRACTION OIL & GAS INC
10459
SI
8/1/2017
WATTENBERG
90750
ADAMS  001
SWSE 14 1S65W 6
320290View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400678168
11/03/2014
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For 1100’ plug: pump plug and displace. If surface casing plug not circulated to surface then tag plug – must be 120’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
EngineerForm: (04)
401903939
02/25/2019
Casing repairs should be pressure tested (>300#) after drilling out and before placing liner (second string). COGCC should be contacted if casing doesn't test.
 
COGIS - Best Management Practice Results
No records to display.