Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-001-07890ANDERSON
2
BAYSWATER EXPLORATION & PRODUCTION LLC
10261
PA
12/20/2012
SUN
80200
ADAMS  001
NWNE 10 2S61W 6
320068View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
2170337
08/10/2012
1) Provide 24 hour notice of MIRU to Randy Edelen at 970-520-2531 or e-mail at Randy.Edelen@state.co.us. 2) For 670’ plug: pump plug and displace, shut-in, WOC 4 hours and tag plug, must be 280’ or shallower. Leave at least 100’ cement in the casing for each plug. If 260’ plug not circulated to surface top off surface with 10 sx. 3) Properly abandon flowlines as per Rule 1103.
EngineerForm: (06)
2170337
08/10/2012
File Form 15 Pit Report for pit(s) present even if at common battery, if pit to be closed file Form 27 for prior approval of remediation.
PermitForm: (04)
400591691
05/02/2014
PER RULE 1003.e.(3) OPERATOR SHALL SUBMIT SUNDRY NOTICE REPORTING SITE IS READY FOR INTERIM RECLAMATION INSPECTION WHEN VEGETATION REACHES 80% COVERAGE. Approval of this Sundry Notice does not constitute approval of Interim Reclamation. Interim Reclamation will be approved by the field inspection conducted after submittal of another Sundry Notice reporting vegetation has reached 80% coverage and site is ready for inspection of Interim Reclamation.
 
COGIS - Best Management Practice Results