Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07283CARNEY C T
24X35
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NWNE 35 2N102W 6
314804View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/2/1999MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/25/2003Facility ID: 150200
DocNum:893633Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameCARNEY C T
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:CORRECT UIC VIOLATION
Test Date:8/25/1999
Field Rep:
Approved Date:10/21/1999
Approved by:ADKINS, JAIME
Last Approved MIT:10/20/1998
Injection/Producing Formation Zones:WEBR
Perforation Interval:5903-6486
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6497
Top Packer Depth:5741
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE775
5 MIN CASE780
CASE BEFORE
FINAL CASE775
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-15
START CASE790
No channel test.