Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09282LACY, S B
2AX
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
10/12/2022
RANGELY
72370
RIO BLANCO  103
NWSW 24 2N103W 6
315805View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/11/2000MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/14/2003Facility ID: 150200
DocNum:853308Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLACY, S B
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:
Test Date:4/21/2000
Field Rep:
Approved Date:6/15/2000
Approved by:ADKINS, JAIME
Last Approved MIT:7/22/1999
Injection/Producing Formation Zones:WEBR
Perforation Interval:5941-6567
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6586
Top Packer Depth:5821
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE890
5 MIN CASE890
CASE BEFORE
FINAL CASE900
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN-10
START CASE890
No channel test.