Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05599EMERALD
3
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/17/2015
RANGELY
72370
RIO BLANCO  103
SWSW 30 2N102W 6
314397View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/30/1999MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/14/2003Facility ID: 150200
DocNum:852672Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/18/1999
Field Rep:ADKINS, JAIME
Approved Date:7/22/1999
Approved by:ADKINS, JAIME
Last Approved MIT:2/28/1995
Injection/Producing Formation Zones:WEBR
Perforation Interval:5678 - 6413
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6347
Top Packer Depth:5366
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE770
5 MIN CASE770
CASE BEFORE0
FINAL CASE770
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE770
No channel test.