Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-01031LEVISON
12
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
3/1/2021
RANGELY
72370
RIO BLANCO  103
SENW 26 2N102W 6
314243View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/23/2024MIT Assigned By:
Date Recv'd:8/23/2024Facility ID: 
DocNum:403899279Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameLEVISON
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:8/22/2024
Field Rep:Browning, Chuck
Approved Date:8/26/2024
Approved by:
Last Approved MIT:1/8/2020
Injection/Producing Formation Zones:WEBR
Perforation Interval:6090-6748
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6106
Top Packer Depth:5892
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1320
5 MIN CASE1325
FINAL CASE1320
FINAL TUBE1542
INITIAL TUBE1542
LOSS OR GAIN-15
START CASE1335
No channel test.