Form 27/27A | Related Doc |
Date Submitted: | 8/5/2024 |
Date Recv'd: | 8/5/2024 | Assigned by: | Nick Cholas |
DocNum: | 403869856 | Facility ID: | 445935 |
Document Type: | FORM 27 | Project Number: | 36658 |
Operator Information: |
Operator: | KERR MCGEE OIL & GAS ONSHORE LP |
Oper. No. | 47120 |
Address: | P O BOX 173779 DENVER CO 80217-3779 |
Type Of Facility: | SPILL OR RELEASE |
Fac. Name | Morton 9 10 15 16 24-1 Facility |
County Name: | WELD |
Operator contact: | Erik Mickelson |
qtrqtr: NESE | section: 1 | township: 1N | range: 67W | meridian: 6 |
|
Remediation Details: |
|
Reason for Report: OTHER |
Cause of Condition: SITE/FACILITY CLOSURE |
Potential Receptors: Irrigation canal 110 feet (ft) west. Water well 200 ft southeast. Occupied buildings 450 ft southeas |
|
HOW REMEDIATE: | Potential impacts that meet the criteria in Rule 912.b. will be reported to the Director in accordance with that Rule and a site-specific soil and/or groundwater remediation plan will be developed and submitted to the ECMC via a supplemental Form 27 in accordance with Rule 913. If reportable impacts are not encountered, a supplemental Form 27 requesting closure will be submitted within 90 days following completion of sampling activities. Field screening and applicable laboratory analytical results will be reported in all submittals. E&P waste records of material transported off-site are kept on file and available upon request. |
|
INITIAL ACTION: | This form has been prepared in accordance with ECMC Rule 911.a to provide prior notice of closure of the Morton 9 10 15 16 24-1 production facility, plugging and abandonment of the Morton 10, 16, 24-1 wellheads and the removal of the associated flowlines. The flowlines will be permanently removed. The off-location flowline system pre-removal notice was submitted under Form 44 Document No. 403828281. Visual inspection and field screening of soils will be conducted following decommissioning of the associated infrastructure, around the wellheads and associated flowlines will be conducted during sampling activities. Soil vapor screening will also be performed around each of the wellheads. Based on these observations, soil and groundwater (if present) samples will be collected and submitted for laboratory analysis of the ECMC full Table 915-1 to determine if soils are in compliance. The topographic Site Location Map showing the geographic setting of the site is provided as Figure 1. |
|
RECLAMATION PLAN: | The site will be reclaimed in accordance with ECMC 1000 Series Reclamation Rules. |
|
SOURCE REMOVED: | If a suspected release is identified and confirmed through soil screening and/or laboratory analysis, soils will be removed and transported to a licensed disposal facility. Disposal records will be kept on file and available upon request. |
|
Correspondence Log: |
Final Resolution | Date | Case Closed? | Letter Sent? | CECMC Person | N/A | N | | Nick Cholas | | N/A | N | | Alexander Ahmadian | |
|
|
Coordinates: |
Type | Facility ID | Facility Name/Num | Lat/Long |
Remediation | 424483 | MORTON 10-1 | 40.076515/-104.833431 |
|
Remediation | 424488 | MORTON 24-1 | 40.076517/-104.833356 |
|
Remediation | 424491 | MORTON 16-1 | 40.076518/-104.833243 |
|
Facility | 445935 | MORTON 24-1 | 40.076930/-104.833680 |
|
Remediation | 488429 | Morton 24-1 Wellhead | 40.076517/-104.833356 |
|
Remediation | 488923 | Morton 9 10 15 16 24-1 Facility | 40.076941/-104.833307 |
|