Skip to Main Content

Incident Search

COGIS - Remediation Reports
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
TANK BATTERY445935MORTON
24-1
KERR MCGEE OIL & GAS ONSHORE LP
47120
AC
1/1/1900
WATTENBERG
90750
WELD  123
NESE 1 1N67W 6
424490View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:8/5/2024
Date Recv'd:8/5/2024Assigned by:Nick Cholas
DocNum:403869856Facility ID: 445935
Document Type:FORM 27 Project Number:36658
Operator Information:
Operator:KERR MCGEE OIL & GAS ONSHORE LP
Oper. No.47120
Address:P O BOX 173779  DENVER  CO 80217-3779
Type Of Facility:SPILL OR RELEASE
Fac. NameMorton 9 10 15 16 24-1 Facility
County Name:WELD
Operator contact:Erik Mickelson
qtrqtr: NESEsection: 1township: 1Nrange: 67Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
GROUNDWATER UTBD Groundwater Samples/Laboratory Analytical Results
SOILS UTBD Soil Samples/Laboratory Analytical Results
Reason for Report: OTHER
Cause of Condition: SITE/FACILITY CLOSURE
Potential Receptors: Irrigation canal 110 feet (ft) west. Water well 200 ft southeast. Occupied buildings 450 ft southeas
 
HOW REMEDIATE:  Potential impacts that meet the criteria in Rule 912.b. will be reported to the Director in accordance with that Rule and a site-specific soil and/or groundwater remediation plan will be developed and submitted to the ECMC via a supplemental Form 27 in accordance with Rule 913. If reportable impacts are not encountered, a supplemental Form 27 requesting closure will be submitted within 90 days following completion of sampling activities. Field screening and applicable laboratory analytical results will be reported in all submittals. E&P waste records of material transported off-site are kept on file and available upon request.
 
INITIAL ACTION:  This form has been prepared in accordance with ECMC Rule 911.a to provide prior notice of closure of the Morton 9 10 15 16 24-1 production facility, plugging and abandonment of the Morton 10, 16, 24-1 wellheads and the removal of the associated flowlines. The flowlines will be permanently removed. The off-location flowline system pre-removal notice was submitted under Form 44 Document No. 403828281. Visual inspection and field screening of soils will be conducted following decommissioning of the associated infrastructure, around the wellheads and associated flowlines will be conducted during sampling activities. Soil vapor screening will also be performed around each of the wellheads. Based on these observations, soil and groundwater (if present) samples will be collected and submitted for laboratory analysis of the ECMC full Table 915-1 to determine if soils are in compliance. The topographic Site Location Map showing the geographic setting of the site is provided as Figure 1.
 
RECLAMATION PLAN:  The site will be reclaimed in accordance with ECMC 1000 Series Reclamation Rules.
 
SOURCE REMOVED:  If a suspected release is identified and confirmed through soil screening and/or laboratory analysis, soils will be removed and transported to a licensed disposal facility. Disposal records will be kept on file and available upon request.
 
Correspondence Log:
Final Resolution
DateCase Closed?Letter Sent?CECMC Person
N/ANNick Cholas
N/ANAlexander Ahmadian
 
Coordinates:
TypeFacility IDFacility Name/NumLat/Long
Remediation424483MORTON
10-1
40.076515/-104.833431

Remediation424488MORTON
24-1
40.076517/-104.833356

Remediation424491MORTON
16-1
40.076518/-104.833243

Facility445935MORTON
24-1
40.076930/-104.833680

Remediation488429Morton 24-1 Wellhead
40.076517/-104.833356

Remediation488923Morton 9 10 15 16 24-1 Facility
40.076941/-104.833307