Skip to Main Content

Incident Search

COGIS - Remediation Reports
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION482390Drake
4N64W17 1-24
PDC ENERGY INC
69175
AC
1/1/2025
 
 
WELD  123
SWNW 17 4N64W 6
482390View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:2/7/2024
Date Recv'd:2/7/2024Assigned by:Kyle Waggoner
DocNum:403678776Facility ID: 482390
Document Type:FORM 27 Project Number:33991
Operator Information:
Operator:PDC ENERGY INC
Oper. No.69175
Address:1099 18TH STREET SUITE 1500  DENVER  CO 80202
Type Of Facility:LOCATION
Fac. NameDrake
County Name:WELD
Operator contact:Jason Davidson
qtrqtr: SWNWsection: 17township: 4Nrange: 64Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
GROUNDWATER NNot impacted Not encountered
SOILS YRefer to Tables 1-4 and Figure 3 Confirmation Soil Sampling
Reason for Report: SPILL
Cause of Condition: SPILL OR RELEASE
Potential Receptors: Closest Domestic Well – 1285’ W Nearest Surface Water – Unnamed Drainage – 540’ SE There are no add
 
HOW REMEDIATE:  Refer to the Source Removal Summary Section above.
 
INITIAL ACTION:  On 11/9/2023, a drilling hose ruptured and resulting in a surface release of approximately 26 bbls of drilling mud, all contained on location. Approximately 24 bbls of standing liquid were collected using vacuum trucks immediately following the release. The saturated road base material beneath the standing liquid was excavated and transported offsite for disposal. Five confirmation soil samples were collected on 11/10/2023 to determine if all impacted road base had been removed. The samples were submitted to Summit Scientific in Golden, CO for analysis of the full ECMC Table 915-1 analytical suite by ECMC approved methods. Three of the five soil samples exceeded the ECMC Table 915-1 standards for petroleum constituents. Concentrations of arsenic exceeded its ECMC Table 915-1 Residential Soil Screening Level (RSSL) and concentrations of barium exceeded its Table 915-1 Protection of Groundwater Soil Screening Level (PGWSSL) in all five samples. Concentrations of selenium also exceeded its Table 915-1 PGWSSL in one of the five samples. Lastly pH levels exceeded its ECMC Table 915-1 standard in two of the five samples.
 
MONITORING PLAN:  Groundwater was not encountered during excavation activities at the Site.
 
RECLAMATION PLAN:  The Drake 4N64W17 1-24 Pad is an active facility and there are no current plans for decommissioning or reclamation activities.
 
SOURCE REMOVED:  Approximately 24 bbls of standing liquid were collected using vacuum trucks immediately following the release. The saturated road base material beneath the standing liquid was excavated and transported offsite for disposal. However, residual soil impacts remain. After the drilling equipment has been removed from the site, additional excavation will be completed in the impacted area and confirmation soil samples will be collected and analyzed for the full list of Table 915-1 analytes.
 