WELL05-103-07426UNION PACIFIC
78X-21
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/15/2019
RANGELY
72370
RIO BLANCO  103
SWSE 21 2N102W 6
314857View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:11/13/2023MIT Assigned By:
Date Recv'd:11/13/2023Facility ID: 
DocNum:403593786Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:760 HORIZON DRIVE STE 401  GRAND JUNCTION  CO 81506
Type Of Facility:Well Status: 
Facility NameUNION PACIFIC
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:11/9/2023
Field Rep:Browning, Chuck
Approved Date:11/16/2023
Approved by:
Last Approved MIT:4/19/2019
Injection/Producing Formation Zones:WEBR
Perforation Interval:6120-6477
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6309
Top Packer Depth:6045
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1300
5 MIN CASE1305
FINAL CASE1300
FINAL TUBE2120
INITIAL TUBE2120
LOSS OR GAIN-10
START CASE1310
No channel test.