TANK BATTERY482821Koch Tank Battery
KP KAUFFMAN COMPANY INC
46290
AC
9/8/2022
 
 
ERIE/WELD  123
NENE 6 1n68w 6
460724View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:9/29/2022
Date Recv'd:9/29/2022Assigned by:Kari Brown
DocNum:403166227Facility ID: 482821
Document Type:FORM 27 Project Number:25978
Operator Information:
Operator:KP KAUFFMAN COMPANY INC
Oper. No.46290
Address:1700 LINCOLN ST STE 4550  DENVER  CO  80203
Type Of Facility:SPILL OR RELEASE
Fac. NameKoch Tank Battery Separator
County Name:WELD
Operator contact:John Peterson
qtrqtr: NENEsection: 6township: 1Nrange: 68Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
SOILS UTBD Inspection/soil samples/laboratory analytical results
Reason for Report: OTHER
Cause of Condition: SITE/FACILITY CLOSURE
Potential Receptors: Approximately 1 resident, and possibly 1 habitable structures are within a quarter mile of the Tank
 
HOW REMEDIATE:  Potential impacts that meet the criteria in Rule 912.b. will be reported to the Director in accordance with that Rule and a site-specific soil and/or groundwater remediation plan will be developed and submitted to the COGCC via a supplemental Form 27 in accordance with Rule 913. If reportable impacts are not encountered, a supplemental Form 27 requesting closure will be submitted within 90 days following completion of sampling activities. Field screening and applicable laboratory analytical results will be reported in all submittals. E&P waste records of material transported off-site are kept on file and available upon request. Operator will submit Form 27 within 45 days of site investigation completion, detailing the findings and completion of the P&A activities.
 
INITIAL ACTION:  This form has been prepared to provide prior notice of the plugging and abandonment of the KOCH Tank Battery, the associated onsite flowline, separator, and produced water vessel, which is the production facility for the Kenneth E Koch 1, and the Koch 41-6. The off location flowline system pre-removal notice was submitted under Form 44 Doc. 403059200, this document has Bulthaup-61N68W-BATT6NENE listed which is the name of the associated facility being removed prior to COGCC renaming and creating the Koch Tank Battery Facility. The facility is shared with Kerr McGee (the Bulthaup is Kerr McGee). Only the KPK tank Battery, Separator, produced water vessel, and associated flowlines are being removed. In accordance with COGCC Rule 911.a., soil and groundwater (if present) samples will be collected and submitted for laboratory analysis to determine if concentrations and values are in compliance with COGCC Table 915-1. Visual inspection and field screening of soils around the header, separator, and associated tanks will be conducted during sampling activities. Soil vapor screening will also be conducted around the facility. The topographic Site Location Map showing the geographic setting of the site is provided as Figure 1. Site still has an active battery present by another operator.
 
MONITORING PLAN:  If groundwater is encountered during decommissioning and/or abandonment activities, a grab sample will be collected as soon as practical. If contaminated soil is in contact with groundwater or if free product/hydrocarbon sheen are observed, the release will be reported in accordance with Rule 912.b. Groundwater samples will be submitted for laboratory analysis of BTEX, naphthalene, 1,2,4-trimethylbenzene, and 1,3,5-trimethylbenzene by EPA Method 8260.
 
RECLAMATION PLAN:  The site will be reclaimed in accordance with COGCC 1000 Series Reclamation Rules. The surface owner is planning an industrial development on this quarter section.
 
SOURCE REMOVED:  If a suspected release is identified and confirmed through soil screening and/or laboratory analysis, soils will be removed and transported to a licensed disposal facility. Disposal records will be kept on file and available upon request.
 
Correspondence Log:
Final Resolution
DateCase Closed?Letter Sent?CECMC Person
N/ANLaurel Anderson
N/ANKari Brown
N/ANAlexander Ahmadian
 
Coordinates:
TypeFacility IDFacility Name/NumLat/Long
Facility482821Koch Tank Battery
40.079624/-105.037601

Remediation483548Koch Tank Battery
40.079578/-105.037613

Remediation483852Koch Tank Battery Separator
40.080040/-105.037670