Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05512EMERALD
37
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/17/2020
RANGELY
72370
RIO BLANCO  103
NWNE 36 2N103W 6
314377View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/9/2022MIT Assigned By:
Date Recv'd:8/9/2022Facility ID: 
DocNum:403130944Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:760 HORIZON DRIVE STE 401  GRAND JUNCTION  CO 81506
Type Of Facility:Well Status: 
Facility NameEMERALD
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:8/8/2022
Field Rep:Browning, Chuck
Approved Date:8/16/2022
Approved by:
Last Approved MIT:2/6/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:5808-6436
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6312
Top Packer Depth:5528
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1240
5 MIN CASE1245
FINAL CASE1240
FINAL TUBE1560
INITIAL TUBE1560
LOSS OR GAIN-10
START CASE1250
No channel test.