Skip to Main Content

Incident Search

COGIS - Remediation Reports
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION331492Ione 2N66W/8NWNE
Battery
CRESTONE PEAK RESOURCES OPERATING LLC
10633
AC
6/1/2024
WATTENBERG
90750
WELD  123
NWNE 8 2N66W 6
331492View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:1/14/2022
Date Recv'd:1/14/2022Assigned by:Peter Gintautas
DocNum:402927140Facility ID: 331492
Document Type:FORM 27 Project Number:21576
Operator Information:
Operator:EXTRACTION OIL & GAS INC
Oper. No.10459
Address:555 17TH STREET SUITE 3700  DENVER  CO 80202
Type Of Facility:LOCATION
Fac. NameIone 2N66W/8NWNE
County Name:WELD
Operator contact:Jacob Evans
qtrqtr: NWNEsection: 8township: 2Nrange: 66Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
SOILS UNo known impacts Investigation pending.
Reason for Report: SPILL
Cause of Condition: MULTIPLE
Potential Receptors: None observed.
 
HOW REMEDIATE:  As needed, site specific soil and/or groundwater remediation plans will be developed and submitted to COGCC via supplemental Form 27.
 
INITIAL ACTION:  This form has been prepared to support replacement of the production equipment associated with this location. In accordance with COGCC Rule 911 and Rule 915, initial representative soil samples will be collected beneath the produced water vessel. Initial laboratory soil analysis will include only BTEX, 1,2,4 and 1,3,5 Trimethylbenzene, naphthalene, TPH, pH, EC, SAR, boron and metals in soils according to Table 915-1. If other equipment are replaced such as the ECDs, meter sheds, or other qualifying equipment, then the soils beneath each will be field screened, and a lab analysis submitted if impacts are identified. Groundwater, if present, will also be collected and analyzed. Identified impacts will be reported as required for each discovery, and a Form 19 will be submitted, and remedial investigation will be conducted with excavation equipment.
 
RECLAMATION PLAN:  No reclamation will be performed on the site unless the entire facility is removed from service or the activities migrate outside the original facility footprint. If these occur, the disturbance will be reclaimed in accordance with 1000 Series Rules, in collaboration with the landowner, and reported in a Form 4 (Sundry Notice) with proper documentation to demonstrate compliance with requirements for final reclamation.
 
SOURCE REMOVED:  If a suspected release is identified and confirmed through soil screening and/or laboratory analysis during decommissioning of the PWV, soils may be removed and transported to a licensed disposal facility. Transport and disposal records will be kept on file under usual and customary practice and are available upon request. If all source material cannot be removed during excavation activities, additional methodologies will be proposed in subsequent Form 27 supplementals.
 
Correspondence Log:
Final Resolution
DateCase Closed?Letter Sent?CECMC Person
N/ANKari Brown
N/ANLaurel Anderson
N/ANLaurel Anderson
N/ANLaurel Anderson
N/ANKari Brown
N/ANLaurel Anderson
N/ANPeter Gintautas
N/ANKari Brown
N/ANKari Brown
 
Coordinates:
TypeFacility IDFacility Name/NumLat/Long
Facility331492Ione 2N66W/8NWNE
Battery
40.159264/-104.799812

Remediation481376Ione 2N66W/8NWNE
40.159264/-104.799812

Remediation481393Ione 8HZ
40.159143/-104.799232