Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06112FEE
24
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/1/2017
RANGELY
72370
RIO BLANCO  103
NWSW 17 2N102W 6
336556View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/18/2021MIT Assigned By:
Date Recv'd:6/18/2021Facility ID: 
DocNum:402723491Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameFEE
Operator contact:ANITA  SANFORD
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:6/17/2021
Field Rep:Browning, Chuck
Approved Date:6/22/2021
Approved by:
Last Approved MIT:4/5/2017
Injection/Producing Formation Zones:WEBR
Perforation Interval:6247-6500
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6231.6
Top Packer Depth:6018.6
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1260
5 MIN CASE1260
FINAL CASE1260
FINAL TUBE1639
INITIAL TUBE1639
START CASE1260
No channel test.