SPILL OR RELEASE461702V-5020 Level Sight Glass
CHEVRON USA INC
16700
CL
9/7/2021
 
 
RIO BLANCO  103
NESE 32 2N102W 6
314646View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:4/6/2021
Date Recv'd:4/6/2021Assigned by:Kris Neidel
DocNum:402649181Facility ID: 461702
Document Type:FORM 27 Project Number:18442
Operator Information:
Operator:SCOUT ENERGY MANAGEMENT LLC
Oper. No.10779
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:SPILL OR RELEASE
Fac. NameV-5020 Level Sight Glass
County Name:RIO BLANCO
Operator contact:Cody Christian
qtrqtr: NESEsection: 32township: 2Nrange: 102Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
SOILS UTBD Samples
Reason for Report: SPILL
Cause of Condition: SPILL OR RELEASE
Potential Receptors: 
 
FURTHER SITE INV:   Initial soil samples from spill area are needed to either close project or determine if further delineation of site is required. Soil sampling results will determine next phase in remediation or Chevron will request closure of assigned REM with supporting documents if impacts are not identified.
 
HOW REMEDIATE:  -If impacts are not identified on initial sampling results, request for NFA/closure will be submitted. -If impacts are identified, timeline of closure will be delayed and will be updated in supplemental Form 27(s).
 
INITIAL ACTION:  A spill of 21.03 bbl oil and 1.98 bbl PW to SPCC bermed area occurred when a level sight glass on V-5020 (free water knockout) at the Rangely Main Water Plant broke (above ground). The sight glass was isolated immediately upon detection. Majority of top 2-4" of soil media under/around V-5020 is gravel mixed with dirt. Media below gravel line was compacted/frozen and soak in at this level was negligible. Some fluids gathered around a discharge pipe at the north end of the vessel. These fluids followed a weep hole next to the pipe and followed the pipe underground and then exited the vessel pad at a lower level. This lower level is also part of the SPCC bermed area. All effected media has been removed and taken to the CVX Rangely Land Farm, and the area has been water washed. The soil around the previously mentioned sub-surface pipe was hydrovac'd and replaced with clean fill dirt. Per Kris Neidel's note on the Initial Spill Report, a Form 27 Remediation workplan will be submitted prior to closure. Root cause of leak is still under investigation, will include preventative measure in spill closure report. NTL-3A has been submitted to BLM. Nearest surface water is Stinking Water Creek. Proposed Sampling Plan
 
RECLAMATION PLAN:  Reclamation/seeding will not be part of this project. Release area was confined to working surface of facility.
 
SOURCE REMOVED:  Approximately 230 cubic yards of impacted soil was removed as part of the initial spill response. Impacted soil was taken to Rangely Landfarm for disposal
 
Correspondence Log:
 
Coordinates:
TypeFacility IDFacility Name/NumLat/Long
Facility461702V-5020 Level Sight Glass
40.098225/-108.860953