Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06159UNION PACIFIC
47-21
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
1/31/2023
RANGELY
72370
RIO BLANCO  103
NWNW 21 2N102W 6
314584View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:3/12/2018MIT Assigned By:
Date Recv'd:3/12/2018Facility ID: 
DocNum:401570482Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameUNION PACIFIC
Operator contact:DIANE  PETERSON
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:REPLACE 187 JOINTS 2 7/8" FIBERLINED TUBING AND PACKER. WELL TO BE RETURNED TO ACTIVE INJECTION
Test Date:3/9/2018
Field Rep:Browning, Chuck
Approved Date:3/15/2018
Approved by:
Last Approved MIT:8/26/2015
Injection/Producing Formation Zones:WEBR
Perforation Interval:6222-6300
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6193.3
Top Packer Depth:5985.2
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1200
5 MIN CASE1205
FINAL CASE1200
LOSS OR GAIN-10
START CASE1210
No channel test.