Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05825GRAY B
17
SCOUT ENERGY MANAGEMENT LLC
10779
AC
5/1/2023
RANGELY
72370
RIO BLANCO  103
SESE 12 2N103W 6
314492View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/22/2014MIT Assigned By:Covington, Dave
Date Recv'd:4/23/2014API number: 05-103-05825
DocNum:2125020Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: AC
Well Name/No.GRAY B
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SESE section: 12 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:4/22/2014
Field Rep:Covington, Dave
Approved Date:4/23/2014
Approved by:Covington, Dave
Last Approved MIT:11/20/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6487-6785
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6294
Top Packer Depth:6279
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE350
5 MIN CASE350
CASE BEFORE
FINAL CASE350
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE350
No channel test.