Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-001-09261HSR-FULENWIDER
6-10
MCCARTNEY ENGINEERING LLC
55030
PA
9/25/2019
BANNER
5190
COMMERCE CITY/ADAMS  001
SENW 10 2S66W 6
320415View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-001-09261Name: HSR-FULENWIDER #6-10
Location: SENW 10 2S66WLat: 39.894594   Long: -104.764486
Operator #: 55030Operator Name: MCCARTNEY ENGINEERING LLC
Inspection Date: 2/4/2011Inspector: Jim Precup
Inspection was: Unsatisfactory
Insp. Type: PRInsp. Stat: PRReclamation (Pass, Interim Or Fail):  P&A (Pass/Fail): 
Brhd. Pressure: Inj. Pressure: T-C Ann. Pressure: UIC Violation Type: 
Violation: YNOAV Sent: NDate Corrective Action Due: 3/4/2011Date Remedied: N/A
 
Tank Battery Equipment    Fiberglass Tanks: 1
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
ACTION PLACARD TANKS / REPAIR SILT FENCE / PLACE SIGN ON WELLHEAD
GENHOUSE NO PLACARDING / SILT FENCE IN DISREPAIR/ NO SIGN ON WELLHEAD
MISC PLUNGER LIFT SYSTEM
TANKBAT 2 300 BBL UPRIGHT / FIBERGLASS TANK / BERM / FENCE / SIGN/ HORIZONTAL SEPARATOR / BIRDGUARD / BERMED / FENCE / METER RUN / 2 PHASE SEPARATOR / METER RUN /



 