Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-10670M.C. HAGOOD A
19X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/1/2022
RANGELY
72370
RIO BLANCO  103
NWSE 15 2N103W 6
316495View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:1/21/2008MIT Assigned By:KOEHLER, BOB
Date Recv'd:1/24/2008API number: 05-103-10670
DocNum:200189378Facility Status:IJ
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: IJ
Well Name/No.M.C. HAGOOD A
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: NWSE section: 15 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:CONVERTED PRODUCTION WELL TO INJECTION WELL. REPLACE 202 JOINTS TUBING W/NEW FIBERLINED TUBING.
Test Date:1/16/2008
Field Rep:
Approved Date:6/25/2008
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:6415-6731
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6401
Top Packer Depth:6315
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE800
Channel TestTest Date
CBL 6/30/2006