Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07589CARNEY C T
32X-34
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/1/2019
RANGELY
72370
RIO BLANCO  103
NWNE 34 2N102W 6
314940View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/27/2012MIT Assigned By:KOEHLER, BOB
Date Recv'd:10/1/2012Facility ID: 150200
DocNum:1772042Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameCARNEY C T
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:Liner: Run 5-1/2" 17# liner surface to 5409'.
Test Date:9/26/2012
Field Rep:
Approved Date:10/2/2012
Approved by:KOEHLER, BOB
Last Approved MIT:5/14/2008
Injection/Producing Formation Zones:WEBR
Perforation Interval:5692-6488
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5464
Top Packer Depth:5373
Multiple Packers:Y
 
Condition of approval:
Top of 1st 5" liner (January 1986) is 5409' so Top Packer depth acceptable. Bottom of perfs probably inaccurate; CICR set at 6288' (1st string) and 6290' (1st liner) at 2 different times and squeezed. Also 100 sx squeeze of 1st liner; 6238'-6243'.
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE1750
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE1750
No channel test.