WELL05-103-05483MCLAUGHLIN, S W
1
SCOUT ENERGY MANAGEMENT LLC
10779
AC
11/4/2022
RANGELY
72370
RIO BLANCO  103
NWSE 33 2N102W 6
314369View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/9/2012MIT Assigned By:KOEHLER, BOB
Date Recv'd:8/13/2012Facility ID: 150200
DocNum:1772017Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, S W
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:FISH LEAKING PACKERS, ADD PERF, RUN 158 JTS FIBERLINED TUBING AND NEW PACKERS
Test Date:7/23/2012
Field Rep:
Approved Date:8/16/2012
Approved by:KOEHLER, BOB
Last Approved MIT:6/1/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:5618-6427
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5625
Top Packer Depth:5543
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE1180
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN-20
START CASE1200
No channel test.