Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08704CHEVRON FEE
130X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NWNW 20 2N102W 6
315559View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/19/2011MIT Assigned By:KOEHLER, BOB
Date Recv'd:10/26/2011API number: 05-103-08704
DocNum:1771540Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:WELLWell Status: AC
Well Name/No.CHEVRON FEE
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: NWNW section: 20 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:FEE 130X WAS SHUT IN 12/2/2010 DUE TO LOW PRODUCTION AND HIGH WATER CUT-EVALUATING FOR ESP (ELECTRIC SUBMERSIBLE PUMP). JOB SCOPE-CLEAN OUT AND SET PACKER, TEST CASING.
Test Date:10/13/2011
Field Rep:
Approved Date:10/27/2011
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:6090-6467
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5956
Top Packer Depth:5919
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE500
5 MIN CASE500
CASE BEFORE
FINAL CASE500
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE500
No channel test.