WELL05-103-10338GRAY B
23X
SCOUT ENERGY MANAGEMENT LLC
10779
PR
5/1/2018
RANGELY
72370
RIO BLANCO  103
NENW 18 2N102W 6
316350View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:2/2/2010MIT Assigned By:KOEHLER, BOB
Date Recv'd:2/4/2010API number: 05-103-10338
DocNum:1770130Facility Status:PR
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:WELLWell Status: PR
Well Name/No.GRAY B
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: NENW section: 18 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:RAN 5 1/2" LINER (FORM 5 SUBMITTED 1/24/2010).
Test Date:2/1/2010
Field Rep:
Approved Date:2/9/2010
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6375-6573
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6200
Top Packer Depth:6169
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE800
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE800
Channel TestTest Date
CBL 1/27/2010