Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05632UNION PACIFIC
4-29
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/18/2022
RANGELY
72370
RIO BLANCO  103
NESW 29 2N102W 6
314404View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:7/14/2009MIT Assigned By:KOEHLER, BOB
Date Recv'd:7/15/2009Facility ID: 150200
DocNum:1769464Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:Set plug in on/off tool, circulated packer fluid, re-tested integrity of casing. This verifies this well has a tubing leak, well will remain shut in and on well work schedule to have tubing replaced. The repair schedule will be re-evaluated to push wells that we can not set plugs in to the top of work schedule.
Test Date:7/1/2009
Field Rep:
Approved Date:7/16/2009
Approved by:KOEHLER, BOB
Last Approved MIT:9/8/2004
Injection/Producing Formation Zones:WEBR
Perforation Interval:5637-6282
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6088
Top Packer Depth:5276
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE780
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN-40
START CASE820
No channel test.