Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06201LARSON, F V
B-8
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/9/2017
RANGELY
72370
RIO BLANCO  103
NESE 26 2N102W 6
314605View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/9/2008MIT Assigned By:KOEHLER, BOB
Date Recv'd:10/14/2008Facility ID: 150200
DocNum:1618905Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLARSON, F V
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:CHANGE OUT 182 JOINTS 2 7/8" TUBING WITH NEW FIBERLINED TUBING
Test Date:10/6/2008
Field Rep:
Approved Date:10/16/2008
Approved by:KOEHLER, BOB
Last Approved MIT:5/10/2006
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6068-6487
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6033
Top Packer Depth:5882
Multiple Packers:Y
 
Condition of approval:
186' BETWEEN TOP PACKER AND TOP OPEN HOLE OK-RPK.
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE810
CASE BEFORE
FINAL CASE810
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE810
No channel test.