Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05809MCLAUGHLIN, A C
7
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/17/2023
RANGELY
72370
RIO BLANCO  103
SWNE 14 2N103W 6
314483View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/20/2007MIT Assigned By:ADKINS, JAIME
Date Recv'd:8/22/2007Facility ID: 150200
DocNum:1618119Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:Run 4 1/2" liner
Test Date:8/16/2007
Field Rep:
Approved Date:10/24/2007
Approved by:ADKINS, JAIME
Last Approved MIT:5/20/2003
Injection/Producing Formation Zones:WEBR
Perforation Interval:6496-6572
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.75
Tubing Depth:6448
Top Packer Depth:6365
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE825
5 MIN CASE825
CASE BEFORE0
FINAL CASE825
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE825
Channel TestTest Date
CBL 7/20/2000
TEMPERATURE SURVEY 7/20/2000
TRACER SURVEY 7/20/2000