Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08105EMERALD
73X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NESW 30 2N102W 6
315225View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/23/2003MIT Assigned By:KRABACHER, JAY
Date Recv'd:10/29/2003API number: 05-103-08105
DocNum:1191065Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210
Type Of Facility:WELLWell Status: AC
Well Name/No.EMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: NESW section: 30 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:6/19/2003
Field Rep:
Approved Date:10/29/2003
Approved by:KRABACHER, JAY
Last Approved MIT:9/2/1998
Injection/Producing Formation Zones:WEBR
Perforation Interval:5695 - 6318
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5583
Top Packer Depth:5546
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE845
5 MIN CASE845
CASE BEFORE0
FINAL CASE840
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE850
No channel test.