Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05486CARNEY
9-35
SCOUT ENERGY MANAGEMENT LLC
10779
AC
5/1/2023
RANGELY
72370
RIO BLANCO  103
NENW 35 2N102W 6
336553View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:1/27/2015MIT Assigned By:Browning, Chuck
Date Recv'd:1/28/2015Facility ID: 150200
DocNum:1171754Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameCARNEY
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:1/27/2015
Field Rep:Browning, Chuck
Approved Date:1/27/2015
Approved by:Browning, Chuck
Last Approved MIT:2/11/2011
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:5833-6475
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5169.5
Top Packer Depth:5137
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE300
5 MIN CASE300
CASE BEFORE0
FINAL CASE300
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE300