Form 21 | Related Doc | Date Submitted: | 9/24/2014 | MIT Assigned By: | Browning, Chuck | Date Recv'd: | 9/29/2014 | Facility ID: | 150200 | DocNum: | 1171727 | Facility Status: | AC | Operator Information: | Oper. No. | 16700 | Operator: | CHEVRON PRODUCTION COMPANY | Address: | 100 CHEVRON RD RANGELY CO 81648 | Type Of Facility: | UIC ENHANCED RECOVERY | Well Status: AC | Facility Name | MCLAUGHLIN, S W | Operator contact: | DIANE PETERSON | Location: | | qtrqtr: SENE | section: 16 | township: 2N | range: 103W | meridian: 6 |
| MIT Details: | Test Type: | 5-YEAR UIC TEST | Test Date: | 9/24/2014 | Field Rep: | Browning, Chuck | Approved Date: | 9/24/2014 | Approved by: | Browning, Chuck | Last Approved MIT: | 4/13/2010 | Injection/Producing Formation Zones: | WEBR | Perforation Interval: | 5524-6362 | Open Hole Interval: | NA | Bridge/Cement Plug Depth: | NA | Tubing Size: | 2.875 | Tubing Depth: | 6202 | Top Packer Depth: | 5332 | Multiple Packers: | Y | | Condition of approval: | | Test Data: | Wellbore Channel Test: | Reading Type | Pressure | 10 MIN CASE | 1225 | 5 MIN CASE | 1225 | CASE BEFORE | 0 | FINAL CASE | 1225 | FINAL TUBE | 1805 | INITIAL TUBE | 1805 | LOSS OR GAIN | 0 | START CASE | 1225 |
| No channel test. |
|
|
|
|
|