Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07191CARNEY UNIT
2X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/1/2019
RANGELY
72370
RIO BLANCO  103
NENE 4 1N102W 6
314772View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:3/26/2014MIT Assigned By:BROWNING, CHUCK
Date Recv'd:3/27/2014Facility ID: 150200
DocNum:1171594Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameCARNEY UNIT
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:3/26/2014
Field Rep:BROWNING, CHUCK
Approved Date:3/26/2014
Approved by:BROWNING, CHUCK
Last Approved MIT:5/19/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:5625-6382
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6108.5
Top Packer Depth:5558.4
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1190
5 MIN CASE1195
CASE BEFORE0
FINAL CASE1190
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE1200
No channel test.