Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07591FEE
93X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/16/2014
RANGELY
72370
RIO BLANCO  103
NENE 33 2N102W 6
314941View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/12/2011MIT Assigned By:BROWNING, CHUCK
Date Recv'd:4/26/2011Facility ID: 150200
DocNum:1171296Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:4/12/2011
Field Rep:BROWNING, CHUCK
Approved Date:4/12/2011
Approved by:BROWNING, CHUCK
Last Approved MIT:5/2/2006
Injection/Producing Formation Zones:WEBR
Perforation Interval:5669-6451
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6276
Top Packer Depth:5373.4
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE810
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE810
No channel test.