Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06278MCLAUGHLIN, S W (SIDETRACK)
6
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/1/2023
RANGELY
72370
RIO BLANCO  103
SESW 33 2N102W 6
314648View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/13/2011MIT Assigned By:BROWNING, CHUCK
Date Recv'd:4/21/2011Facility ID: 150200
DocNum:1171282Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, S W (SIDETRACK)
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:4/13/2011
Field Rep:COLER, LARRY
Approved Date:4/21/2011
Approved by:BROWNING, CHUCK
Last Approved MIT:5/24/2006
Injection/Producing Formation Zones:WEBR
Perforation Interval:6046-6467
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5102.7
Top Packer Depth:5038.5
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE850
5 MIN CASE850
CASE BEFORE0
FINAL CASE850
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE850
No channel test.