Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09186UNION PACIFIC
143Y28
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
SWNW 28 2N102W 6
315759View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/6/2007MIT Assigned By:KRABACHER, JAY
Date Recv'd:5/21/2007API number: 05-103-09186
DocNum:1170948Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: AC
Well Name/No.UNION PACIFIC
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SWNW section: 28 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:4/3/2007
Field Rep:
Approved Date:5/21/2007
Approved by:KRABACHER, JAY
Last Approved MIT:8/7/2001
Injection/Producing Formation Zones:WEBR
Perforation Interval:5699 - 6411
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5653
Top Packer Depth:5620
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE805
5 MIN CASE805
CASE BEFORE0
FINAL CASE805
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE805
No channel test.