WELL05-103-08029FEE
113X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/15/2022
RANGELY
72370
RIO BLANCO  103
SESE 19 2N102W 6
315175View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/9/2005MIT Assigned By:KRABACHER, JAY
Date Recv'd:6/3/2005Facility ID: 150200
DocNum:1170702Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/3/2005
Field Rep:KRABACHER, JAY
Approved Date:5/12/2005
Approved by:KRABACHER, JAY
Last Approved MIT:9/13/2000
Injection/Producing Formation Zones:WEBR
Perforation Interval:5754 - 6469
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5719
Top Packer Depth:5494
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE815
5 MIN CASE820
CASE BEFORE0
FINAL CASE815
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-5
START CASE820