Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06019COLTHARP W H
A-1
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/1/2022
RANGELY
72370
RIO BLANCO  103
SESW 35 2N102W 6
314535View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/12/2005MIT Assigned By:KRABACHER, JAY
Date Recv'd:4/14/2005Facility ID: 150200
DocNum:1170686Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON TEXACO GLOBAL TRADING
Address:6275 SIMMS #300  ARVADA  CO 80004
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameCOLTHARP W H
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:replace 174 jts of 2.875" tubing
Test Date:4/8/2005
Field Rep:
Approved Date:4/14/2005
Approved by:KRABACHER, JAY
Last Approved MIT:4/30/2003
Injection/Producing Formation Zones:WEBR
Perforation Interval:5641 - 6366
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5522
Top Packer Depth:5436
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE800
No channel test.