Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05632UNION PACIFIC
4-29
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/18/2022
RANGELY
72370
RIO BLANCO  103
NESW 29 2N102W 6
314404View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/9/2004MIT Assigned By:KRABACHER, JAY
Date Recv'd:10/8/2004Facility ID: 150200
DocNum:1170670Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:CASING LEAK
Repair Desc:isolate and cement CSG leak. replace 170 jts tubing
Test Date:9/8/2004
Field Rep:
Approved Date:10/8/2004
Approved by:KRABACHER, JAY
Last Approved MIT:9/30/1999
Injection/Producing Formation Zones:WEBR
Perforation Interval:5637 - 6282
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5411
Top Packer Depth:5275
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE770
5 MIN CASE795
CASE BEFORE0
FINAL CASE755
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-50
START CASE805
No channel test.