Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08760CHEVRON FEE
135X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
SWSE 28 2N102W 6
315581View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/24/2004MIT Assigned By:KRABACHER, JAY
Date Recv'd:9/30/2004API number: 05-103-08760
DocNum:1170651Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: AC
Well Name/No.CHEVRON FEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SWSE section: 28 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:5/21/2004
Field Rep:
Approved Date:9/30/2004
Approved by:KRABACHER, JAY
Last Approved MIT:12/10/1999
Injection/Producing Formation Zones:WEBR
Perforation Interval:5614 - 5965
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5468
Top Packer Depth:5425
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE810
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE810
No channel test.