Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06258RAVEN
A-4
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/31/2022
RANGELY
72370
RIO BLANCO  103
SWNE 31 2N102W 6
396937View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/12/1999MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/28/2003Facility ID: 150200
DocNum:814454Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameRAVEN
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:"WORKOVER" -- REMAINS SHUT IN
Test Date:9/21/1999
Field Rep:
Approved Date:10/21/1999
Approved by:ADKINS, JAIME
Last Approved MIT:1/23/1997
Injection/Producing Formation Zones:WEBR
Perforation Interval:5653 - 5664
Open Hole Interval:5686 - 6291
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6256
Top Packer Depth:5569
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE770
5 MIN CASE770
CASE BEFORE0
FINAL CASE750
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-20
START CASE770
No channel test.