Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06154U P
14-20
SCOUT ENERGY MANAGEMENT LLC
10779
PR
3/1/2018
RANGELY
72370
RIO BLANCO  103
NESW 20 2N102W 6
314579View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-103-06154Name: U P #14-20
Location: NESW 20 2N102WLat: 40.126740   Long: -108.869640
Operator #: 16700Operator Name: CHEVRON USA INC
Inspection Date: 9/25/1995Inspector: Debbie Baldwin
Inspection was: No Satisfactory/Unsatisfactory Indicator
Insp. Type: Insp. Stat: Reclamation (Pass, Interim Or Fail): P&A (Pass/Fail): 
Brhd. Pressure: Inj. Pressure: T-C Ann. Pressure: UIC Violation Type: 
Violation: NOAV Sent: Date Corrective Action Due: N/ADate Remedied: N/A
 
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
HISTORICAL LEAK OCCURRED AT A WELD IN A 4", CEMENT LINED, WATER INJECTION LINE., CAUSED BY INTERNAL CORRSION. APPROX 5 BBL SPILLED, FLUID RAN 25YD TOWARD STINKIN WATER WASH. 1-2 BBL RAN INTO THIS DRY WASH, NO VISIBLE SHEEN, NO RECOVERY. DAMAGED SECTION OF PIPE REPLACED WITH NEW PIPE. SPILL CALLED IN BY J.K. INBODY



 


Tuesday, November 12, 2024