Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06278MCLAUGHLIN, S W (SIDETRACK)
6
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/1/2023
RANGELY
72370
RIO BLANCO  103
SESW 33 2N102W 6
314648View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:2/19/2024MIT Assigned By:
Date Recv'd:2/19/2024Facility ID: 
DocNum:403691385Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameMCLAUGHLIN, S W (SIDETRACK)
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:2/15/2024
Field Rep:Browning, Chuck
Approved Date:2/21/2024
Approved by:
Last Approved MIT:6/20/2019
Injection/Producing Formation Zones:WEBR
Perforation Interval:6046-6467
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5102
Top Packer Depth:5038
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1275
5 MIN CASE1275
FINAL CASE1275
FINAL TUBE2076
INITIAL TUBE2076
LOSS OR GAIN5
START CASE1270
No channel test.