Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07581FEE
85X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
1/1/2024
RANGELY
72370
RIO BLANCO  103
SESE 29 2N102W 6
314936View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:1/25/2024MIT Assigned By:
Date Recv'd:1/25/2024Facility ID: 
DocNum:403666352Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameFEE
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:UIC Repair - Repair sunken wellhead and surface casing. RIH w/ injection equipment well ready to RTI pending an approved Form 21.
Test Date:1/24/2024
Field Rep:Browning, Chuck
Approved Date:1/25/2024
Approved by:
Last Approved MIT:1/8/2020
Injection/Producing Formation Zones:WEBR
Perforation Interval:5566-6329
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5586
Top Packer Depth:5498
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1310
5 MIN CASE1310
FINAL CASE1310
LOSS OR GAIN-15
START CASE1325
No channel test.