Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-01030LEVISON
8
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/5/2021
RANGELY
72370
RIO BLANCO  103
NESW 26 2N102W 6
336549View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:12/1/2023MIT Assigned By:
Date Recv'd:12/1/2023Facility ID: 
DocNum:403612276Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameLEVISON
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:11/30/2023
Field Rep:Browning, Chuck
Approved Date:12/6/2023
Approved by:
Last Approved MIT:5/16/2019
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:5975-6403
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6338
Top Packer Depth:5878
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1375
5 MIN CASE1360
FINAL CASE1375
FINAL TUBE1585
INITIAL TUBE1585
LOSS OR GAIN25
START CASE1350
No channel test.